Finding out why an event was not delivered
Use this page when an outside system says it did not get an event, or got it late. You will use the Event monitor first, then the Delivery log.
Before you start
- You hold the role
ADMINand can open Enterprise. - You know what the event was about: the kind of record (for example a receipt) and its number, or about when it happened.
Steps
- Switch to Enterprise and open
Integration > Event Monitor. - Filter by
Entity(for examplereceipt) andKey(the receipt number). Find the event. - No row at all? The event was never written. Go to "The event does not exist" below.
- Read
Statusand follow the table.
Status of the event | What it means | Next step |
|---|---|---|
new | The delivery worker has not handled it yet. It takes up to 100 events every few seconds (5 by default). | Wait a minute and press Refresh. If it stays new, the delivery worker may not be running: ask whoever runs the app server. |
skipped | No active subscriber matched the event. | Open Subscribers. Is the subscriber Active? A subscriber made on the screen matches every event. A built-in subscriber matches only its own events. |
partial | At least one delivery is still waiting. | Open the Delivery log (step 5). |
failed | At least one delivery used up its tries. | Open the Delivery log (step 5). |
sent | All handled deliveries were sent. A poll subscriber is not counted. | If the receiver says it got nothing, check whether the subscriber is a poll one: nothing is sent to it. |
- Open
Integration > Delivery Log. FilterEvent IDwith the id you saw. There is one row for each subscriber. - Read the row:
Status | Attempts | HTTP Code | Last Error | Cause |
|---|---|---|---|---|
pending | 0 | empty | empty | Not tried yet, or Max Retries is 0, or the subscriber is poll. |
pending | 1 or more | any | text | A try failed. The next try waits Retry Delay × 2^n seconds. |
processing | any | empty | empty | A try is running, or a worker stopped during it. After 60 seconds it can be taken again. |
failed | equals Max Retries | 500, 404, ... | HTTP {code}: ... | The receiver answered with an error. Fix the receiver. |
failed | equals Max Retries | empty | a network error text | The receiver could not be reached, or did not answer in 30 seconds. |
failed | 0 | empty | No webhook URL configured | The subscriber has no URL. |
failed | 0 | empty | unknown delivery method {value} | The subscriber's Delivery is queue or another value the worker does not know. |
failed | 0 or more | empty | no internal handler registered for subscriber {code} | An internal subscriber with a code the system does not handle. |
sent | 1 or more | 200 to 299 | empty | Delivered. The receiver accepted it. |
A failed delivery is not tried again. No retry button or API method for it was found in the code.
The event does not exist
The event may not have been written:
- It is a record-change event (
bio.{table}.{operation}). It is written only if the Event registry holds an active row with that exact code. Open the registry and checkActive. - It is a business event (
process.*). The business command writes it in the same transaction as the change. If the command was refused or rolled back, there is no event. Check the business screen. - It was written under another warehouse. The
Warehousecolumn shows the storage name. Check you are looking for the right one.
The registry check does not apply to process.* events: switching them off in the registry does not stop them.
Related pages
- Event monitor
- Delivery log
- Subscribers
- Event and delivery statuses
- API: